Strany 1 - Installation

Wireless Thermostat Installation Guide

Strany 2

Zoned SystemsControl4 supports zoned HVAC systems using a zoning panel. If used, however, a common wire needs to be installed at the Thermostat. Power

Strany 3 - Table of Contents

Place the Wireless Thermostat in a proper location to ensure its eciency and to avoid unnecessary cycling of the furnace or air conditioner.a. Plac

Strany 4

Thread the wires from the wall through the back of the large rectangu-lar opening in the new rear plate (see Figure 3), and then position the new rear

Strany 5 - General Description

Select the desired power supply method by enabling or disabling power stealing on the back of the Thermostat faceplate.• Disable (recommended). Power

Strany 6 - Requirements

16Install the CR123A (3V) battery (included) in the Thermostat faceplate according to the polarity labels—POS (+) and NEG (-)—on the Thermostat’s cir

Strany 7 - Specifications

Composer Programming InstructionsAll advanced programming must be completed by a Control4 Dealer using Composer Pro. To see what advanced programming

Strany 8

PropertiesFahrenheit or Celsius: Sets the temperature display in Fahrenheit or Celsius. View/Edit Schedule: Select to access and edit the Thermostat s

Strany 9 - Supported System Types

Time FormatDate Format: Sets the format preferences for date (MM/DD/YYYY or DD/MM/YYYY).Time Format: Sets the format preferences for time (12h or 24h)

Strany 10 - Remote Temperature Sensor

to 2 degrees, the heating system will engage until reaching 70 degrees Fahrenheit.Cooling Cuto Point: Sets the temperature for the cooling system to

Strany 11 - Installation Instructions

Maximum Run Time: Sets the maximum time heating or cooling will run before turning o. To adjust, use the up and down arrows. Example: If cooling or h

Strany 12 - Figure 4. Screw Holes

DisclaimerTrademarksWarrantyControl4® makes no representations or warranties with respect to any Control4 hardware, software, or the contents or use o

Strany 13

Thermostat RelaysThis section shows the relays that are engaged during heating and cooling for the various Wire-less Thermostat configurations.Conventi

Strany 14

Primary Fan (Electric), Secondary Fan (Electric)Stage Y1 Y2 W1 W2 O B G1st Stage * *2nd Stage * * *• The switch in the fuel position causes the Therm

Strany 15

Primary Fan (Electric), Secondary Fan (Electric)Stage Y1 Y2 W1 W2 O B G1st Stage * *2nd Stage * * *Primary Fan (Fuel), Secondary Fan (Electric)Stage Y

Strany 16 - Properties

Primary Fan (Electric), Secondary Fan (Fuel)Stage Y1 Y2 W1 W2 O B G1st Stage * * *2nd Stage * * * *3rd Stage (Before Aux Stage Delay)* * * * *Auxiliar

Strany 17 - Advanced Device Configuration

Primary Fan (Electric), Secondary Fan (Electric)Stage Y1 Y2 W1 W2 O B G1st Stage * * *2nd Stage * * * *3rd Stage * * * * *E-Heat (Stage 1)* * *• The

Strany 18

Heat Pump: CoolingPrimary Fan (Fuel), Secondary Fan (Fuel)Stage Y1 Y2 W1 W2 O B G1st Stage * * *2nd Stage * * * *Primary Fan (Electric), Secondary Fan

Strany 19 - Auxiliary Stage

TroubleshootingIf the Thermostat is not working:1. Ensure that the HVAC system is not turned OFF.2. Check for proper wiring (see “Sample Wiring Confi

Strany 20 - Thermostat Relays

Installing a Bypass Resistor to Enable Power Stealing on a Wireless ThermostatAlthough Control4 recommends using a common wire to provide power to the

Strany 21 - Conventional Stage: Cooling

Access the 24V transformer and integrated control panel on the HVAC system. This typically requires removing the front panel of the furnace. Remember

Strany 22 - Heat Pump: Heating

25Figure 7. Gas/Electric Single Stage

Strany 23

Table of ContentsiiiSupported Model ... 1Impo

Strany 24

Loosen the screw on the heat terminal (typically marked ‘W’ or ‘W1’) and secure one end of the resistor in the HVAC system’s Heat Relay Terminal by ti

Strany 25 - Heat Pump: Cooling

Example 2. This second example (Figure 9) shows a control board that does not provide a common wire screw terminal. In this example, an additional len

Strany 26 - Troubleshooting

Sample Wiring ConfigurationsWARNING! Do not install LINE VOLTAGE wires to a LOW VOLTAGE wire. IMPORTANT! When utilizing power stealing, Control4 recomm

Strany 27 - Wireless Thermostat

29Wiring ConnectionsTerminal DescriptionRH 24VAC power for heating—connect to low voltage heating system transformer. (See Note 1 below.)RC 24VAC pow

Strany 28 - Figure 6. Bypass Resistor

30Figure 10. Conventional, Single Stage Wiring

Strany 29

31Figure 11. Conventional, Dual Stage Wiring

Strany 30 - Terminal (W)

32Figure 12. Heat Pump, Single Stage Wiring

Strany 31

33Figure 13. Heat Pump with Electric Auxilliary Heat, Dual Stage Wiring

Strany 32 - Sample Wiring Configurations

34Figure 14. Millivolt Heat, Conventional Cool, Single Stage Wiring

Strany 33 - Wiring Connections

35Figure 15. Heat Pump with Electric Auxilliary, Dual Stage, Dual Transformer Wiring

Strany 35

Regulatory ComplianceTo review regulatory information for your particular Control4 products, see the information located on the Control4 website at: h

Strany 36

Supported ModelCCZ-T1-W Wireless Thermostat - WhiteWARNING! Install in accordance with all national and local electrical codes.WARNING! This pro

Strany 37

Box Contents• Wireless Thermostat• CR123A (3V) battery• 3 screws (#6 x 1-inch sheet metal screws)• 3 plastic wall anchors (#4-6 x 7/8”)• Warranty

Strany 38

SpecificationsFront and Rear ViewFigure 1. Faceplate Figure 2. Rear PlateRecommended Wiring: 22 AWG (36 ft. max.) 18 AWG (100 ft. max.)Power Sour

Strany 39

IMPORTANT! The Wireless Thermostat has ‘power stealing’ enabled by default, however, it is recommended to power the Thermostat with a common wire. If

Strany 40 - Warranty

• New construction, Control4 recommmends these options:• Install a common wire.• Use a Remote Temperature Sensor in the wall where the Thermostat i

Komentáře k této Příručce

Žádné komentáře